Graco Inc. 308-548 Paint Sprayer User Manual


 
308-548 9
Startup
INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
starting or spraying accidentally
. Fluid
under high pressure can be injected through the
skin and cause serious injury
. T
o reduce the risk of
an injury from injection, splashing fluid, or moving
parts, follow the
Pressure Relief Procedure
whenever you:
D
are instructed to relieve the pressure,
D
stop spraying,
D
check or service any of the system equipment,
D
or install or clean the spray tip.
WARNING
Pressure Relief Procedure
1.
Engage the gun safety latch.
2.
T
urn the ON/OFF switch to OFF
.
3.
Unplug the power supply cord.
4.
Disengage the gun safety latch. Hold a metal part
of the gun firmly to a grounded metal pail. T
rigger
the gun to relieve pressure.
5.
Engage the gun safety latch.
6. Open the pressure drain valve. Leave the pressure
drain valve open until you are ready to spray
again.
If you suspect that the spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following the steps above
, VER
Y SLOWL
Y loos
-
en the tip guard retaining nut or hose end coupling to
relieve pressure gradually
, then loosen completely
.
Now clear the tip or hose obstruction.
Startup Procedure
Use
this procedure each time you start the sprayer to
help ensure the sprayer is ready to operate and that
you start it safely
.
NOTE:
If this is a first-time startup, flush the sprayer
.
See page 13.
NOTE:
Refer to Fig. 9 and the other figures referenced
in the text as you start the sprayer
.
1.
Open the pressure drain valve (42).
See Fig. 7.
2. Don’t install the spray tip until the pump is
primed!
Open
or drain, position
Fig.
7
1
1
42
04648
3. T
urn the pressure knob (64) to the minimum
setting.
4. Disengage the gun trigger safety
.
See Fig. 3,
page 7.
CAUTION
Do not run the sprayer dry for more than 30 sec
-
onds to avoid damaging the pump packings.
5. T
o prime the pump,
turn the sprayer switch (52)
on.
Slowly increase the pressure until the sprayer
starts. When fluid comes from the pressure drain
valve, close the valve.