Start-Up
4. Dial up 90-100 psi of pressure at solvent regulator.
5. Using a proper collection container, open solvent
ÀXVKYDOYHDWWKH,1'\JXQ(QVXUHWKDW\RXKDYH
SURSHUVROYHQWÀXVKLQJDWWKHJXQ
Catalyst
5.
While continuing to hand prime the pump, trigger gun
into suitable collection container.
6. Continue to hand prime the pump, with trigger pulled
DQGLQVSHFWWKHÀRZRIFDWDO\VWIURPQR]]OH
7. Once all air is evacuated and a steady stream of
catalysts observed, the system is primed with catalyst.
8. Release trigger and stop hand priming.
9.6ROYHQWÀXVKJXQ
2. Turn the catalyst slave
pump yellow ball valve to the
open position.
3. Hand prime the pump
until a steady stream of catalyst
ÀRZVEDFNWRWKHERWWOH
4. Close the ball valve. Hand
VWURNHWKHSXPSXQWLOLWGHYHORSHV
100-200 PSI.
1. 3XOODQGURWDWH3LYRWNQRE
to disengage the catalyst drive
arm.
14 GC-1392Z