20 GC-1412D
The following assumes that all connections are tight.
System Start-Up Instructions
1. Select a clean dry air supply.
2. Attach a 3/8” or larger air hose to the Air Manifold
Inlet. 'RQRWXVHTXLFNGLVFRQQHFW¿WWLQJV
3. Attach grounding clamp assembly, P/N 17440-00, to
the slave pump.
Attach Here
4. Securely attach Clamp, P/N 7749-00, to permanently
grounded rod or pipe.
Before turning on main air, check all On/Off Ball Valves,
making certain all Valves are in the “Off” position and set
all regulators in their “Off” position. (Turn knob counter-
clockwise for OFF or reduced pressure setting.)
5. Place the mixing element straight into the front gun
housing. (refer to spray gun user manual)
6. Place the retaining nut along with the spray tip and
spray tip spacer onto the gun housing. (refer to spray
gun user manual)
7. Push the slide valve to the open position.
8. 2SHQWKHDLUYDOYHSQRQWKHVROYHQWWDQNDQG
adjust the solvent pressure to 90 PSI (6.2 bar). Open
WKHEDOOYDOYHSQRQWKHVROYHQWWDQN1H[W
open ball valve p/n 23518-00 on the gun to verify that
VROYHQWZLOOÀRZRXWRIWKHIURQWRIWKHJXQWKURXJKWKH
dispense tip, then close the valve.
Do not exceed 20 PSI (1.4 bar)on the material
UHJXODWRUXQWLODVWHDG\PDWHULDOÀRZKDVEHHQ
established.