Setup
312001G 11
2. Separate prime tube (smaller)
from suction tube (larger).
3. Place prime tube in waste
pail.
4. Submerge suction tube in
water or flushing solvent.
5. Turn Prime/Spray Valve to
PRIME.
6. Plug sprayer in a grounded outlet.
7. Turn power switch ON.
8. Align setting indicator with
Prime/Clean setting on
Pressure Control knob until
pump starts, page 9.
9. When sprayer starts pumping, flushing solvent
and air bubbles will be purged from system.
Allow fluid to flow out of prime tube, into waste
pail, for 30 to 60 seconds.
10. Turn power switch OFF.
11. Transfer suction tube to
paint pail and submerge
suction tube in paint.
12. Turn power switch ON.
13. When you see
paint coming out
of prime tube:
a. Point gun into
waste pail.
b. Unlock gun
trigger lock.
c. Pull and hold
gun trigger.
d. Turn
Prime/Spray
valve to
SPRAY.
14. Continue to trigger gun into waste pail until you
see only paint coming out of gun.
15. Release trigger.
Engage trigger
lock.
16. Transfer prime
tube to paint
pail and clip
prime tube to
suction tube.
ti2039a
ti9652a
ti9651a
ti9346a
ti5580a
ti9718a
• Motor stopping indicates pump and hose
are primed with paint.
• If motor continues to run the sprayer is not
properly primed. To reprime repeat step 8.
ti2810a
ti9653a
ti5580a
ti9345a
(SG10)
ti8922a
ti8909a
(SG20)
(SG10)
ti8923a
ti8908a
(SG20)