Graco Inc. X5 Paint Sprayer User Manual


 
Operation
312001G 9
Operation
Trigger Lock
Always engage the trigger lock when you stop
spraying to prevent the gun from being triggered
accidentally by hand or if dropped or bumped.
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever
you stop spraying and before cleaning, checking,
servicing, or transporting equipment.
1. Turn power switch OFF and unplug
power cord.
2. Turn Prime/Spray valve to
PRIME to relieve pressure.
3. Hold gun firmly to
side of pail. Trigger
the gun to relieve
pressure.
4. Engage trigger
lock.
If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved after fol-
lowing the steps above, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve
pressure gradually, then loosen completely. Clear
hose or tip obstruction. Read Unclogging Spray
Tip, page 13.
ti8908a
Trigger Locked (SG20)
Trigger Unlocked (SG20)
ti8909a
Trigger Locked (SG10)
Trigger Unlocked (SG10)
ti8923a
ti8922a
ti2810a
Leave Prime/Spray valve in the PRIME
position until you are ready to spray again.
ti9346a
ti9207a
(SG10)
ti8923a
ti8908a
(SG20)
Pressure Control Knob Settings
High Pressure
Spray
Low Pressure
Spray
Prime/
Clean
Rolling
ti5597a
To select function, align symbol on pressure control knob with setting indicator on sprayer.