Figure 45.
Figure 46.
Main Line
6" Rigid Pipe (0.037) at 20' ................ 0.740
Branch Line
4" Rigid Pipe (0.075) at 10' ................ 0.750
4" Flex Pipe (0.28) at 5' ........................ 1.400
Elbows/Branches
6" 45˚ Y-Branch ................................ 0.329
4" 45˚ Elbow ........................................ 0.225
Additional Factors
Seasoned Filter ................................ 1.000
Total Static Pressure Loss ................ 4.444
Additional Factors Static Pressure
4.
Note: Always account for a seasoned filter,
so you don't end up with a system that only
works right when the filter is clean.
Note: When calculating static pressure loss
to determine if multiple lines can be left open
at the same time, only include the main line
numbers once.
3.
5.
Figure 48
Page 31
ExampleData Sheet Performance
Curve Figure 47
Figure 46
-6-
G0440/G0441/G0443 Cyclone Dust Collectors
.(
(
¿-
+,
,*
&
¿)
'+
,
¿-
('
,
¿-
')
&
¿'
&*
(
¿)
)(
(
¿)
¢,
(,
(
¿)
*.
&
¿&+
('
,
¿-
¢,
('
,
¿-
¢,
&,
&
¿)
G0440 MACHINE
DATA SHEET
Customer Service #: (570) 546-9663 • To Order Call: (800) 523-4777 • Fax #: (800) 438-5901
MODEL G0440
2 HP TWO-STAGE CYCLONE DUST COLLECTOR
©2005 BY GRIZZLY INDUSTRIAL
®
Specications, while deemed accurate, are not guaranteed. 2/2005.
The airow test probe is located 1.5x duct diameter upstream from the
air inlet. Test pipe length is a minimum of 10x duct diameter.
2 HP GRIZZLY DUST COLLECTOR PERFORMANCE RESULTS
Max CFM Max SP HP Volts Inlet Impeller
1354 10.4 2 HP 220V 7" 14-1/2"
Restrictor Plate
(inch)
Dia. 7" Dia.
6"
Dia.
5"
Dia. 4" Dia. 3" Dia.2"
Static Pressure
(Inch/H2O)
2.5 3.2 5.1 7.8 9.2 10.0
CFM 1354 1266 1070 829 586 338
Performance Curve
2500
2250
2000
1750
1500
1250
1000
750
500
250
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0
1354
CFM
STATIC PRESSURE (Inch/H2O)
Figure 47
Accessories Page 34