Grizzly G0555X Cordless Saw User Manual


 
G0555X (Mfg. Since 1/12)
-47-
READ ELECTRICAL SAFETY
ON PAGE 45!
Motor at 220V
1 BLACK
4 YELLOW
Hot
Hot
Ground
Ground
Start
Capacitor
200 MFD
125 VAC
2 GRAY
3 RED
Bl
Wt
Gn
220 VAC
6-15 Plug
ON
OFF
Start
Capacitor
30 MFD
250 VAC
ON/OFF Switch
(viewed from behind)
120 VAC
5-15 Plug
Work Lamp
(40 Watt Maximum)
220V Wiring Diagram
1 BLACK
4 YELLOW
Hot
Hot
Ground
Ground
Start
Capacitor
200 MFD
125 VAC
2 GRAY
3 RED
Bl
Wt
Gn
ON
OFF
Run
Capacitor
30 MFD
250 VAC
220-240 VAC
6-15 Plug
Motor at 220V-240V
ON/OFF Switch
(Switch Viewed from Behind)
NOTICE
To maintain CSA compliance
when the machine is converted to
220V, the work lamp must be
disconnected from power and
removed from the machine as
instructed on Page 11.