Grizzly G4008 Drill User Manual


 
Figure 1.
Grounded Outlet Box
Current
Carrying
Prongs
Grounding Blade Is
Longest Of the Three Blades
Under no circumstances should the grounding
pin from any three-pronged plug be removed. If it
will not fit the outlet, have the proper outlet
installed by a qualified electrician.
Check with a qualified electrician or one of our
service personnel if the grounding instructions
are not completely understood, or if in doubt as to
whether the tool is properly grounded. Use only
3-wire extension cords that have 3-prong ground-
ing type plugs and 3-hole receptacles that accept
the tool’s plug. FIgure 1.
Repair or replace damaged or worn cord immedi-
ately.
-4- G4008/G4009 Drill Press
110V Operation
The G4008/G4009 Drill Press is supplied with a
U.S made 110V/220V motor. Under normal use,
the motor draws approximately 9 amps @ 110V.
We recommend using a 15 amp circuit breaker or
a 15 amp slow blow fuse for 110V operation. This
should be satisfactory for normal use, while pre-
venting motor damage from high heat caused by
overload. If frequent circuit failures occur when
using the drill press, contact our service depart-
ment or your local electrical contractor.
220V: Contact the service department for further
instruction on wiring for 220V.
Grounding
CAUTION: THIS TOOL MUST BE GROUNDED
WHILE IN USE TO PROTECT THE OPERATOR
FROM ELECTRIC SHOCK.
In the event of a malfunction or breakdown,
grounding provides a path of least resistance for
electric current to reduce the risk of electric
shock. This tool is equipped with an electric cord
having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into a
matching outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
Improper connections of the electrical-grounding
conductor can result in risk of electric shock. The
conductor with green or green and yellow striped
insulation is the electrical-grounding conductor. If
repair or replacement of the electric cord or plug
is necessary, do not connect the equipment
grounding conductor to a live terminal.
SECTION 2: CIRCUIT REQUIREMENTS