Grizzly G9860 Biscuit Joiner User Manual


 
Ultimate Series Jointers -5-
SECTION 2: CIRCUIT REQUIREMENTS
220V Operation
The Ultimate Series Jointers have a 3 H.P., 3450
R.P.M. motor which requires a 220V single-phase
circuit. The cord set enclosed does not have a
plug as the style of plug you require will depend
upon the type of service you currently have or
plan to install. The motor will safely draw about 15
amps at 220V under load. If you operate the
Ultimate Series Jointers on any circuit that is
already close to its capacity, it might blow a fuse
or trip a circuit breaker. However, if an unusual
load does not exist, and power failure still occurs,
have the circuit inspected by a qualified electri-
cian.
Circuit Load
When operating at 220V, we recommend using a
NEMA-style 6-15 plug and outlet. See Figure 1.
You may also “hard-wire” the machine directly to
your panel, provided you place a disconnect
switch near the machine. Check the electrical
codes in your area for specifics on wiring require-
ments.
Under normal use, the motor draws approximate-
ly 15 amps at 220V. We recommend a 15 amp cir-
cuit breaker for 220V operation. This should be
satisfactory for normal use while providing
enough protection against circuit damage caused
by power surges. Always check to see if your cur-
rent wires are capable of handling a 15 amp load.
If you are unsure, consult the advice of a qualified
electrician.
Figure 1. Typical 220V 3-prong plug and outlet.