Grizzly H7507 Router User Manual


 


Figure 29.
20.      
      

21. 

      

22. 

If you change router bits, the fence pieces
must be adjusted in/out so there is not more
than
1
8" clearance between the router bit
and the fences.
Dust Collection
DO NOT use the Model H7507 without an ade-
quate dust collection system. An attached
router will create substantial amounts of
wood dust while operating. Failure to use a
dust collection system can result in short
and long-term respiratory illness.
Recommended CFM at Dust Port: 225 CFM
Do not confuse this CFM recommendation with
the rating of the dust collector. To determine the
CFM at the dust port, you must consider these
variables: (1) CFM rating of the dust collector,
(2) hose type and length between the dust col-
lector and the machine, (3) number of branches
or wyes, and (4) amount of other open lines
throughout the system. Explaining how to cal-
culate these variables is beyond the scope of
this manual. Consult an expert or purchase a
good dust collection "how-to" book.



19. 
     
      