Harbor Freight Tools 92185 Nail Gun User Manual


 
Skus
91053, 91054
For technical questions, please call 1-800-444-3353. Page 6
92147, & 92185
Testing the Full Sequential Safety Trip Mechanism
Warning: Even though the nailer should be empty during this procedure,
ALWAYS point the nailer at a piece of scrap wood when testing.
1. Make sure the tool is disconnected from the power supply.
2. Completely empty the Magazine (74) of nails.
3. The Nailer should not fire if the Lower Safety (32) is not depressed against the
workpiece.
Operation
For best service, you should incorporate an oiler, regulator, and inline filter, as
shown in the diagram below. Hoses, couplers, oilers, regulators, and filters are all avail-
able at Harbor Freight Tools.
TO
ROOFING
NAILER
1. To connect this tool, we recommend you use the included quick connector.
Note: If you are not using an automatic oiler system, before operation, add a few
drops of Pneumatic Tool Oil to the airline connection. Add a few drops more after
each hour of continual use.
2. Set the air pressure on your compressor from 75-125 PSI. Do not exceed the
maximum air pressure.
3. Check the air connection for leaks.
Note: The amount of air pressure effects how deep the nails/staples will be
driven. It is suggested that you experiment on scrap material.
4. Check the air connection for leaks and disconnect the Nailer/Stapler.
REV 11/06