Skus
91053, 91054
For technical questions, please call 1-800-444-3353. Page 7
92147, & 92185
LOWER SAFETY (32)
TRIGGER (48)QUICK CONNECTOR (87)
LOWER SAFETY (32)
TRIGGER (48)
4. Make sure the Trigger (48) and Lower Safety (32) move freely, without sticking -
see the illustration below.
5. Connect the air supply to the tool at the Quick Connector (87). Set the regulator at
the recommended 75 to 125 PSI.
6. Test the tool by depressing the Lower Safety (32) against the workpiece without
pulling the Trigger (48). The Tool must not cycle (fire). If it cycles (fires), stop
immediately and have it repaired by a qualified service technician.
7. Hold the tool away or off of the workpiece. The Lower Safety (32) of the tool
should return to its original position. Squeeze the Trigger (48). The tool should
not cycle (fire). If the tool fires, stop immediately and have it repaired by a
qualified service technician.
8. Depress the Lower Safety (32) against the workpiece and squeeze the Trigger
(48). The tool must cycle (fire) only once. Release the Trigger and squeeze it
again. The tool must not cycle (fire). With the Trigger held, carefully lift the
nailer and press it against the workpiece again. The tool must not cycle (fire).
If it fails to perform in the manner explained in bold, have it repaired by a qualified
service technician.
REV 11/06