Page 11For technical questions, please call 1-800-444-3353.SKU 96289
electrical outlet. (This method helps cool
down the Heat Element (11) properly to
extend the life of the Heat Gun.)
CAUTION! Danger of fire. 4. Make sure
to set the Heat Gun on a non-flammable
surface until it has completely cooled.
Once cooled, store the Heat Gun in a 5.
clean, dry, safe location out of reach of
children and other unauthorized people.
To prevent accidents, turn off the tool 6.
and disconnect its power supply after
use. Clean, then store the tool indoors
out of children’s reach.
MAINTENANCE AND
SERVICING
Procedures not specically
explained in this manual must
be performed only by a qualied
technician.
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION: Turn the Power
Switch of the tool off and unplug
the tool from its electrical outlet
before performing any
inspection, maintenance, or
cleaning procedures.
TO PREVENT SERIOUS INJURY
FROM TOOL FAILURE: Do not
use damaged equipment. If
abnormal noise or vibration
occurs, have the problem
corrected before further use.
Cleaning, Maintenance, and
Lubrication
DISCONNECT from power outlet 1.
and make sure that it is completely
cooled.
BEFORE EACH USE,2. inspect the
general condition of the Heat Gun.
Check for loose screws, misalignment
or binding of moving parts, cracked or
broken parts, damaged electrical wiring,
and any other condition that may affect
its safe operation.
AFTER USE, 3. clean the external surfaces
of the tool with a clean, moist cloth and
mild detergent. Then dry. Do not use
solvents.
CAUTION! 4. All maintenance, service,
and repairs not mentioned in this manual
mustonlybeperformedbyaqualied
service technician.
5. WARNING! If the supply cord of
this power tool is damaged, it must be
replaced only by a qualied service
technician.
Troubleshooting
Problem Possible Causes Possible Solutions
Heat Gun will not turn
on.
Power Switch set at “0”.1.
No power at outlet.2.
Cord not connected.3.
Turn Power Switch to “l” or “ll”.1.
Check power at outlet.2.
Check that cord is plugged in.3.
Unsatisfactory results. Improper heat setting.1. Adjust heat setting (“l” or “ll”) for 1.
correct application.
Follow all safety precautions whenever diagnosing or servicing the