HP (Hewlett-Packard) LSG202M Grinder User Manual


 
©Copyright 2008 Liberty Pumps Inc. All rights reserved - 9 -
TROUBLESHOOTING CHART: LSG200
SYMPTOM
1. PUMP WILL NOT START
2. REPEATED TRIPPING
3. PUMP WILL NOT SHUT
OFF
4. LOW FLOW
5. WATER IN OIL CHAMBER
6. WATER INSIDE MOTOR
CASING
POSSIBLE CAUSE
A. Power supply failure
B. Burned out fuse or tripped circuit
breaker
C. Damaged power cable
D. Jammed impeller
E. Water inside motor
A. Circuit protection under-rated
B. Current unbalance
C. Pump connected to incorrect
voltage
D. Wet or damaged wiring
E. Obstruction in pump
F. Incorrect motor rotation
G. Foreign matter build-up
A. Control panel failure
B. Switch Failure
A. Incorrect pump rotation
B. Low liquid level
C. Obstruction in pump or piping
D. Partially closed valve(s)
A. Loose or damaged oil plug
A. Damaged lower lip seal or
mechanical seal
B. Damaged O-Ring between oil
chamber and motor plate
C. Damaged cable
ACTION
A. Check power supply
Check out electrical system for
loose connections
Check operating voltage
B. Check circuit protectors
C. Check external cable for damage
– repair
D. Inspect and remove jamming
object
E. Refer to Symptom 5 and 6
A. Check rating and replace with
proper size
B. Check current draw
C. Verify connections. See wiring
diagram
D. Inspect external cable, replace if
worn or damaged
E. Remove obstruction
F. Check rotation
A. Clean motor housing
B. Check control panel
C. B. Replace the switch
A. Check rotation
B. Check liquid level
C. Remove obstruction
D. Check and adjust valve
A. Check plug and sealing washer
A. Replace seal
B. Replace O-Ring
C. Replace cable
IF SYMPTOMS CONTINUE, CONSULT THE
LIBERTY PUMPS PRODUCT SERVICE DEPT.