Hitachi 309067 Paint Sprayer User Manual


 
8 309067
Intermediate Problem Solving
TYPE OF
PROBLEM
WHAT TO CHECK
If check is OK, go to next check
WHAT TO DO
When check is not OK, refer to this column
Spray pattern
variations
3. Pressure adjustment potentiometer (77) by replacing
with a new one.
3. Replace potentiometer. See page 14..
(continued)
4. Low Output section, page 6.
Motor is hot and
runs intermit-
tently
1. Determine if sprayer was operated at high pressure with
small tips, which causes excessive heat build up.
1. Decrease pressure setting or increase tip
size.
2. Be sure ambient temperature where sprayer is located is
no more than 90
_F (32_C) and sprayer is not located in
direct sun.
2. Move sprayer to shaded, cooler area if
possible.
3. Motor. 3. Replace motor. See page 12.
Building circuit
breaker opens
as soon as
sprayer switch is
1. All electrical wiring for damaged insulation,
and all terminals for loose fit or damage.
Also check wires between pressure transducer
and motor. See page 12.
1. Repair or replace any damaged wiring or
terminals. Securely reconnect all wires.
turned on.
2. For missing motor brush inspection plate gasket (see
page 10), bent terminal forks or other metal to metal
contact points which could cause a short.
2. Correct faulty conditions.
3. Motor armature for shorts. Use an
armature tester (growler) or perform motor test.
See page 9. Inspect windings for burns.
3. Replace motor. See page 12.
4. Motor control board (22a) by performing motor control
board diagnostics on page 13. If diagnostics indicate,
substitute with a good board.
CAUTION: Do not perform this check until motor arma-
ture is determined to be good. A bad motor armature
can burn out a good board
4. Replace board. See page 13.
Circuit breaker
opens after
sprayer oper-
ates for 5 to 10
minutes.
1. Basic Problems Electrical on page 4.
Building circuit
breaker opens
as soon as
sprayer is
plugged into
outlet and
sprayer is not
turned on.
1. ON/OFF switch (80). Be sure sprayer is unplugged!
Disconnect wires from switch. Check switch with
ohmmeter. The reading should be infinity with ON/OFF
switch OFF, and zero with switch ON.
CAUTION: A short in motor circuit can damage switch
and or motor control board (22a).
1. Replace ON/OFF switch. See page 14.
2. For damaged or pinched wires in junction box (20). 2. Replace damaged parts.
Unit will not run
on generator but
does run on AC
power
1. Generator peak voltage.
Sprayer will not run if peak voltage is above 165 or be-
low 75 VAC for 232916, 232917; above 190V or below
100V for 232910 232913, 232919 or above 260V or
below 180V for 232918, 232915, 232914, 232665.
1. Use AC power or a different generator.