Hitachi l300p Welder User Manual


 
12
OPERATION and PROGRAMMING
Shows drive's status.
Press to run the motor.
Press to stop the drive or
reset an alarm.
Lights when the power input to
the drive is ON.
Indicates the unit associated
with the parameter display.
Press to write the new value to
the EEPROM.
Press up or down to sequence through
parameters and functions shown on the
display, and increment/decrement values.
Press to set or monitor a
parameter value.
Parameter Display Power LED
Display Unit LEDs
Potentiometer
Store Key
Up/Down Keys
Monitor LEDs
RUN Key
STOP/RESET Key
Function Key
Displays frequency, motor cur-
rent, rotational speed of the
motor, and an alarm code.
L300P Series can be easily operated with the digital operator (OPE-SR) provided as standard. The Digital operator can
also be detached and used for remote-control. A multilingual (English, French, German Italian, Spanish, and Portuguese)
operator with copy function (SRW-0EX) or a digital operator without potentiometer(OPE-S) is also available as an option.
(For US version, OPE-SRE (English overlay with potentiometer) is provided as standard.)
(
1
)
or the value previously
monitored is displayed.
(
1
)
or the value previously
monitored is displayed.
(
2
)
The motor runs at the frequency
set by the potentiometer.
(
3
)
The motor stops.
(
2
)
Function code appears.
(
3
)
appears.
(
5
)
appears.
(
6
)
Preset value is displayed.
(
7
)
Newly set value is displayed.
(
8
)
Returns to and
the setting is complete.
(
4
)
or the code
number set in the end of
last setting is displayed.
(
1
)
or the value previously
monitored is displayed.
1. Setting the maximum output frequency
2. Running the motor(by potentiometer)
3. Monitoring output current value
(
Output frequency monitor
)
FUNC
STR
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
FUNC
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
FUNC
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
MIN MAX
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
Power
on
Power
on
Power
on
Press
until appears.
Press
to set desired value.
Press
until
appears.
Press key.
Press key.
Press key.
Press key
to store the value.
*To run the motor, go
back to monitor mode
or basic setting mode.
Press key to stop the motor.
Press key and turn the
potentiometer clockwise.
Press key.
Press key.
(
2
)
Function code appears.
(
3
)
appears.
(
4
)
Output current value
is displayed.
Press
until appears.
FUNC
FUNC
FUNC
FUNC
STR
FUNC
STR STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
FUNC
STR
STOP
RESET
RUN