5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
How to make the batteries perform longer
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a while.
CAUTION
When the battery charger has been continuosly
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
charging has been completed, give 15 minutes rest
until the next charging.
If the battery is rechraged when it is warm due to
battery use or exposure to sunlight, the pilot lamp
may light in green.
The battery will not be recharged. In such a case,
let the battery cool before charging.
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in the Table 3, and batteries that have become
hot should be cooled for a while before being
recharged.
(3) Regarding recharging time
Table 4 Charging time (At 68°F (20°C))
NOTE:
The charging time may vary according to
temperature and power source voltage.
4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
Table 3 Recharging ranges of batteries
Rechargeable Temperatures at which the
batteries battery can be recharged
BSL1830
32°F – 122°F
(0°C – 50°C)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 2, according to the condition of the charger or
the rechargeable battery.
Charger
UC18YRSL
Battery
BSL1830 Approx. 45 min.
Table 2
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Lights continuously
Before
charging
While
charging
Charging
complete
Charging
impossible
Blinks
Lights
Blinks
Flickers
Lights
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
The
pilot
lamp
lights or
blinks in
red.
The
pilot lamp
lights in
green.
Overheat
standby
01Eng_WH18DSDL_US.p65 10/2/12, 2:38 PM12