Hobart Welding Products 1800 Welder User Manual


 
OM-929 Page 13
2-8. Changing Input Voltage From 230 Volts To 200 Volts
Ref. 801 878-B
Cut cable ties as necessary.
1 230 Volt Lead
2 Tubing
Locate lead marked 230 VAC.
Slide tubing down and disconnect
lead splice.
Fold tubing over 230 volt lead stub
and secure.
3 200 Volt Lead
Locate lead marked 200 VAC.
Slide tubing down, and connect 200
volt lead stub to top half of the for-
mer 230 volt lead, and secure with
existing hardware.
Slide tubing over connection and
secure.
Tools Needed:
1
2
3
5/16, 3/8 in
2-9. Electrical Service Guide
Input Voltage 200 230
Input Amperes At Rated Output 30 26
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay
2
35 30
Normal Operating 3 45 40
Min Input Conductor Size In AWG/Kcmil 10 10
Max Recommended Input Conductor Length In Feet (Meters)
97
(29)
128
(39)
Min Grounding Conductor Size In AWG/Kcmil 10 10
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 Time-Delay fuses are UL class RK5 .
3 Normal Operating (general purpose no intentional delay) fuses are UL class K5 (up to and including 60 amp), and UL class H ( 65 amp and
above).