Hobart Welding Products 2250 Welding System User Manual


 
OM-192 440 Page 11
2-5. Installing Work Clamp
1 Work Cable
Route cable out front panel opening
from inside.
2 Negative (–/Black) Output
Terminal
Connect cable to terminal.
3 Hardware
4 Work Clamp
Route cable through clamp handle
and secure as shown.
Close door.
Ref. ST-802 285 / Ref. ST-801 566
Tools Needed:
1/2, 3/4 in
2
1
3
4
2-6. Setting Gun Polarity For Wire Type
Tools Needed:
3/4 in
1
1 Polarity Changeover Label
2 Positive (+/Red) Output
Terminal
3 Negative (–/Black) Output
Terminal
Always read and follow wire
manufacturer’s recommended
polarity.
Close door.
3
2
Ref. ST-801 875
Ref. ST-192 432