SECTION 4 MAINTENANCE AND TROUBLESHOOTING
4-1. Routine Maintenance
Y Disconnect power before maintaining.
3 Months
Replace unreadable labels.
Repair or replace
cracked weld cable.
Clean and tighten weld terminals.
6 Months
Blow out or vacuum
inside. During heavy
service, clean monthly.
OR
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
4-2. Circuit Breaker CB1
Ref. ST-801 789 / Ref. 800 797-C
1 Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2 Welding Gun
Check gun liner for blockage or
kinks.
3 Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
Allow cooling period and reset
breaker. Close door.
1
2