OM-945 Page 21
SECTION 6 − OPERATING THE WELDING GENERATOR
. If the unit is extremely overloaded, weld and generator power will stop. Turn unit off and restart to reset the generator protection circuit and restore
weld generator power output.
. If the rated output of the unit is exceeded, engine speed may vary rapidly until the weld or generator load is reduced.
6-1. Front Panel Controls
Ref.226 427-A
4
1
3
2
1 Engine Control Switch
Use switch to start engine, select speed, and
stop engine. In Run/Idle position, engine runs
at idle speed at no load, and weld/power
speed under load. In Run position, engine
runs at weld/power speed.
2 Engine Choke Control
Use control to change engine air-fuel mix.
To Start: pull out choke and turn Engine Con-
trol switch to Start position. Release switch
and slowly push choke in when engine starts.
. If the engine does not start, let the engine
come to a complete stop before attempt-
ing restart.
. During cold weather some gasoline en-
gines encounter difficulties that are easily
remedied. See Section 6-2 and 10-1.
To Stop: turn Engine Control switch to Off
position.
3 Engine Hour Meter
4 Amperage Control
Use control to select weld amperage. Select
amperage according to electrode being used
(see Section 6-3). Control may be adjusted
while welding. Control does not affect gener-
ator power output.