Husqvarna K3000 Wet Welder User Manual


 
English – 17
MAINTENANCE
Changing the grease
The following parts must be dismantled to change the grease
in the gear housing:
1 Flange washers holding the cutting blade
2 The sealing ring
3 Support flange for the guard
4 Guard for the blade
5 The four screws holding the shield. Lift the shield together
with the drive wheel unit out of the gear housing.
6 Wipe out the grease and fill with new, good quality gear
grease. The gear housing should contain 90 g of grease
in total.
CAUTION! Exercise care when dismantling so as not to
damage the gaskets. These are used both as seals and
spacers for the gear setting.
Checking the drive axle and flange
washers
Check that the threads on the drive shaft are undamaged.
Check that the contact surfaces on the blade and the flange
washers are undamaged, of the correct dimension, clean,
and that they run properly on the drive axle.
Do not use warped, notched, indented or dirty flange
washers. Do not use different dimensions of flange washers.
Checking water connection with flow
limiter
Check and clean the filter in the connection regularly and
change it when needed.
1 Unscrew the connector.
2 Press out the filter (A) using a screwdriver or the like.
3 Clean or change the filter.
4 When refitting - make sure that the flow limiter (B) is
correctly adjusted, with the concave face turned towards
the clutch connection.
Daily maintenance
1 Check that nuts and screws are tight.
2 Check that the power switch unit works smoothly.
3 Clean the outside of the machine.
4 Checking the blade guard
5 Check the condition of the cutting blade.
6 Check and clean the cooling air openings.
7 Check that the cord and extension cord are intact and in
good condition.