230 Volt Operation
If 230V, single phase operation is desired, the following instructions must be followed:
1. Disconnect the machine from the power source.
2. This dust collector is supplied with four motor leads that are connected for 115V operation, as shown
in Figure A. Reconnect these four motor leads for 230V operation, as shown in Figure B.
3. The 115V attachment plug (A), supplied with the dust collector, must be replaced with a UL/CSA
listed plug suitable for 230V operation (D). Contact your local Authorized JET Service Center or
qualified electrician for proper procedures to install the plug. The dust collector must comply with all
local and national codes after the 230 volt plug is installed.
4. The dust collector with a 230 volt plug should only be connected to an outlet having the same
configuration (D). No adapter is available or should be used with the 230 volt plug.
Important: In all cases (115 or 230 volts), make certain the receptacle in question is properly grounded.
If you are not sure, have a registered electrician check the receptacle.