Jet Tools GH-1340W Lathe User Manual


 
1
1
Coolant Preparation
CAUTION
Follow coolant manufacturer's
recommendations for use, care, and
disposal.
1. Remove rear access cover on tailstock
end. Make sure coolant tank has not
shifted during transport and is located
properly under the recovery chute (Fig. 9).
2. Pour three gallons of coolant mix into drip
pan.
3. After machine has been connected to
power, turn on coolant pump and check to
see coolant is cycling properly.
4. Fasten coolant door to stand.
Electrical Connections
WARNING
All electrical connections must be
completed by a qualified electrician!
Failure to comply may cause serious injury
and / or damage to the machinery and
property!
The GH-1340W-1 & GH-1440W-1 Gear Head
Lathes are rated at 3HP, 1Ph, 230V only.
Confirm power available at the lathe's location
is the same rating as the lathe.
The GH-1340W-3 & GH-1440W-3 Gear Head
Lathes are rated at 3HP, 3Ph, 230V/460V
prewired 230V. Confirm power available at
the lathe's location is the same rating as the
lathe.
Lathe Power Source Junction Box:
Remove the cover. Run the main power
through the strain relief bushing and attach the
ground, followed by power leads. Replace the
cover.
Main Power Switch: Located on the
backside of the machine. Turns the power to
the machine on and off.