Jet Tools JWBS-20 Saw User Manual


 
14
Electrical Connections
WARNING!
All electrical connections must be done by a
qualified electrician!
Failure to comply may result in loss of
property and/or serious injury!
JWBS-20 is rated at 2 HP, 1Ph, 230V
only.
A plug needs to be purchased for the bandsaw
that matches the outlet you intend to use (A,
Fig. 23).
Confirm power at the site is the same as the
saw before making any electrical connections.
Review the electrical schematic on page 26.
The on/off switch (B, Fig. 24) is thermally
protected. If the saw motor is overloaded, or a
momentary interruption of electrical current is
sensed, the saw will shut off. Allow a few
minutes for the saw to cool down and reset by
pushing the off button.
Maintenance
Keep bearing guides clean and free of build up.
Do not let saw dust build up in the upper and
lower wheel housings. Vacuum out frequently.
Keep the brake switch, located in the lower
wheel housing, clean and free of saw dust.
Connect the bandsaw to a JET dust collection
system.
Clean and grease the raising/lowering rack for
the upper bearing guides if it becomes difficult
to raise, or lower.
Clean, and oil the tensioning mechanism if it
becomes difficult to adjust.
Vacuum out the motor fan cover.