John Deere AC2-80ES Air Compressor User Manual


 
Stationary Electric Air Compressor Manual 13
1. A qualied electrician MUST hook up the electrical system.
a. Verify the electrical supply at the power source is off.
b. Be certain all switches on the Control Panel are in the "OFF"
position.
c. Make connections to the terminal as shown below.
PREPARATION INSTRUCTIONS
PRE-START CHECKLIST:
1. Check oil level. Add if necessary.
2. Remove any moisture in the air compressor air tank. NEVER
attempt to open the Air Tank Drain Valve when more than 10
PSI is in the air tank! Remove excessive pressure with an air tool,
then open the Air Tank Drain Valve in the bottom of the air tank. Close
tightly when drained.
3. Make sure the Motor/Pressure Switch is in the "OFF" position.
4. Make sure the Safety Relief Valve is working correctly.
5. Make sure all guards and covers are in place and securely mounted.
DANGER
RISK OF ELECTROCUTION!
Improper connection of the
equipment-grounding conductor
can result in a risk of shock or
electrocution. Check with a
qualied electrician or service
personnel if you are in doubt as
to whether the outlet is properly
grounded. The wire with insulation
having an outer surface that is
green with or without yellow
stripes is the grounding wire.
WARNING
RISK OF ELECTRICAL SHOCK!
This product must be grounded. If
there should be a malfunction or
breakdown, grounding provides
a path of least resistance for
electric current to reduce the risk
of electric shock.
WARNING
RISK OF BODILY INJURY!
Never attempt to open the Air
Tank Drain Valve when more
than 10 PSI of air pressure is in
the air tank!
ELECTRICAL:
L1 L2 L3
G
L2
L1
Power
In
1 Phase
electric diagram_industrial line_1 Phase