Preparing the Generator
14 Operator’s Manual
ENGINE OIL
Use oil viscosity based on the expected air temperature
range during the period between oil changes.
Use a high quality detergent oil with API classications of
SJ or higher.
Check oil level before each operation and ensure that it
is maintained.
CAUTION: THIS ENGINE CRANKCASE IS NOT
FILLED WITH OIL AT THE FACTORY, SO BE
SURE TO FILL IT BEFORE OPERATING THE
ENGINE.
ENGINE OIL CAPACITY
NOTE: These engines are equipped with a “Low Oil”
shut-off system for engine protection. If the
engine fails to start, check engine crankcase
for oil.
To ll with oil:
1. Level the engine to ensure accurate inspection and
to prevent overlling.
2. Unscrew the oil gauge (Fig. 1), wipe the dipstick dry.
Reinsert the oil gauge back into the oil ll gauge opening.
Remove the oil gauge and check the oil level.
3. The oil level should be between the full and low marks
on the dipstick. (Fig. 2)
NOTE: When checking the oil be sure the engine is
level.
4. Fill with oil as required through the oil ll gauge
opening.
5. Replace the oil gauge and screw in rmly.
6. Wipe up any spilled oil.
(Fig. 1)
(Fig. 2)
OIL GAUGE
UPPER LEVEL
TEMPERATURE CHART
MODEL # Liters Quart Ounces
AC-G6010H 0.6 0.63 20.3
AC-G6010HE 0.6 0.63 20.3
AC-G6010S 1.2 1.27 40.5
AC-G6010SE 1.2 1.27 40.5
AC-G7510H 1.1 1.16 37.2
AC-G7510HE 1.1 1.16 37.2
AC-G8010S 1.2 1.27 40.5
AC-G8010SE 1.2 1.27 40.5