10-5508 Rev A Service Department (800) 888-700910
Step Two: Install single to double adapter and electrical wires
Take all four electrical wires and insert them, one by one, through the rubber grommet,
and then through the hole. Pull all of the slack into the computer system control box.
Replace the grommet in the hole.
Next, install the single to double adapter. Approach the compressor from the front. The
electrical plug and air valve are on the front.
Front of compressor
Grasp the connector located on the left hand side of the circuit board in slot L1 with the
pliers. Remove the connector located in L1 by pushing down on the board while
pulling up on the connector.
push down on board, pull up on connector