Keiser 1030 Air Compressor User Manual


 
10-5508 Rev A Service Department (800) 888-70092
Solenoid Valve Replacement for 1030/1031 Compressor
*WARNING: Unplug compressor before beginning. Before replacing valve, draw all
of the air out of the compressor by pressing both the + and – buttons on the exercise
equipment. When this is done, shut off valve to exercise equipment by turning the red
handle clockwise. When the valve has been turned off, it should be parallel to the
compressor like this:
The Mac® valve cannot be cleaned. Therefore, once faulty, it must be replaced.
The Allenair® valve functions well in this application, and it can be cleaned.
There are three steps for valve removal:
1 Dismount valves
2 Remove hoses
3 Remove electrical wires from circuit board
Step One: Dismount valve
First, remove the screws on either side of the valve. There are two.
Use the needle nose pliers to grab and hold the nut underneath the valve while using a
Phillips screwdriver to remove the screws from the top.
remove both screws