Kenmore 625.38376 Dust Collector User Manual


 
Before installing the bypass valve, or
copper tube, be sure the turbine and
support are firmly in place in the
valve outlet port.
Turbine
Support Sensor Port
Turbine
FIG. 10
Bypass Valve or
Installation Adaptor
INSTALLING HOLDING CLIPS
Black Clip Cross Section of Valve
Inlet or Outlet
O-Ring
Clip Snaps into Place
Between Larger Diameter Rings FIG. 11
BYPASS VALVE TURNED DOWNWARD
Turn bypass valve upside
down to connect to floor
level plumbing.
FIG. 12
INSTALLING 3 VALVE BYPASS AND PIPES
Complete the following steps to install the three (3)
valve bypass:
Cut the house main water pipe where you will con-
nect the softener.
Loosely put together pipe, fittings, and the three
(3) valves.
Place valve(s) within easy reach.
When all pipe, fittings and valves make a good fit
together, tighten all threaded joints (use pipe dope
on outside threads), or solder all sweat joints.
3 VALVE BYPASS
TO FIG. 13
Softener Inlet
Questions? Call The Kenmore Water Line 1-800-426-9345
12