Kodak 990 Cordless Saw User Manual


 
Voltage requirements
Impedance between neutral and ground wires: less than 2 ohms
Neutral to ground voltage: less than 1 volt AC maximum
Voltage drop across circuit breaker: less than 0.1 volts
Impluse voltage spikes transients: less than 50% of nominal line
voltage
Surge voltage: less than 51 of nominal line voltage
AC power quality and
conditioning
In some locations, even though recommended wiring practices have been
followed, the power reaching the scanner may exhibit unstable power
quality characteristics. System errors and intermittent data loss could
result.
Power conditioning equipment may be required to overcome the power
quality problems. Kodak can make arrangements for an on-site power
analysis in an area with exceptionally unstable power.
Consult with your electrical contractor or utility company to ensure that on-
site wiring complies with the specifications and that wall outlets and comply
with codes
Environmental
requirements
This equipment can operate in a typical office environment under the
following conditions:
Scanner Temperature Relative
Humidity
Heat
Dissipation
9500/990 59° to 86° F
15° to 30° C
15 to 76% 5200 Btu
Dimensions and
weight
This equipment has the following dimensions and weight, with all optional
accessories included:
Scanner Height Width Depth Weight
9500 48 in.
122 cm
29 in.
74 cm
51 in.
130 cm
630 lbs
227 kg
990 48 in.
122 cm
29 in.
74 cm
51 in.
130 cm
785 lbs
356 kg
NOTE: With the Workstation Side Console, the width is 60 in (152 cm).
Space requirements
Adequate work space must be provided to allow normal operation, proper