Lincoln Electric 10476 Welder User Manual


 
A-1
INSTALLATION
A-1
Weight
Including Machine
Torch Cable (Length)
(25ft/7.6m) (50ft/15.2m)
70 lbs. 85 lbs.
32 kg. 39 kg.
INPUT - SINGLE or THREE PHASE / 60 HERTZ ONLY
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
REQUIRED GAS FLOW RATE REQUIRED GAS INLET PRESSURE
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - PRO-CUT 55
Standard Voltage
Duty Cycle
50% Duty Cycle
100% Duty Cycle
Current
Range
25-55 Amps
AC Input
Voltage at
60 Hertz
1Ø - 230
1Ø - 460
3Ø - 230
3Ø - 460
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
70 AMPS
40 AMPS
40 AMPS
20 AMPS
#8 (8.4mm
2
)
#8 (8.4mm
2
)
#10 (5.3mm
2
)
#10 (5.3mm
2
)
Input Supply Wire
Ground Wire
#10 (5.3mm
2
)
#10 (5.3mm
2
)
#10 (5.3mm
2
)
#10 (5.3mm
2
)
Type 75
o
C
Copper Wire in Conduit AWG (IEC) Sizes
Depth
26.0 in.
660 mm
W
idth
11.0 in.
280 mm
Height
12.6 in.
320 mm
Open Circuit
Voltage
MAX
335 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30
o
C or Less
Pilot Current
18 Amps @ 100% Duty Cycle
AMPS
55
40
1Ø Input Current at Rated Output
3Ø Input Current at Rated Output
230/460/1 or 3Ø/60 Hz 230V: 55A @ 50%, 40A @ 100%
460V: 30A @ 50%, 23A @ 100%
Idle Current: 0.42 Amps, Idle Power 98 Watts
@ 230V
230V: 28A @ 50%, 21A @ 100%
460V: 17A @ 50%, 15A @ 100%
70 PSI @ 360 SCFH
( 4.8 Bar. @ 10160 LHR)
80 to 150 PSI
( 5.4 Bar. TO 10.2 Bar.)