Lincoln Electric 2HBG Welder User Manual


 
14
Pipeliner
www.lincolnelectric.com
PIPELINER NR-207XP AWS: E71T8-K6 Self-Shielded Flux-Cored (FCAW-S) Wire Electrode
For consistently high impact values,
choose 207XP. Optimum perfor-
mance on vertical down, hot, fill and
cap passes on standard cross-country
p
ipelines and arctic grade pipe.
Recommended for API Pipe Grades
X42 through X70.
WELDING POSITIONS
ADVANTAGE LINCOLN
Consistently high CVN properties,
even down to -40˚F (-40˚C).
Virtually eliminates CVN values
below 42 ft•lbf (56 joules).
Self-shielded, flux-cored. No need
for external gas or flux.
Produces quality welds in moderate
wind conditions with no tenting.
CONFORMANCE
AWS A5.29-98: E71T8-K6
ASME SFA-5.29: E71T8-K6
Our quality driven manufacturing
system certified to ISO 9001
and our exceptionally high grade
raw materials mean every coil of
I
nnershield delivers great arc
characteristics and superior
feedability.
Manufactured to actual lot control.
Actual certificates of conformance
are available upon request.
TYPICAL APPLICATIONS
Suggested for use on applications
demanding consistently high tough-
ness.
Standard cross country pipelines.
Arctic grade pipe.
1
G
2F
4G
2G
5G
3G
%C %Mn %P %S %Si %Al %Ni %Cr %Mo %V
Requirements
AWS E71T8-K6
.15 .50- .03 .03 .80 1.80 .40- .20 .15 .05
max. 1.50 max. max. max. max. 1.00 max. max. max.
Typical Results .055 .98 .009 <.003 .07 .80 .61 .04 .03 <.003
DEPOSIT COMPOSITION
- As Required per AWS A5.29
DIAMETERS / PACKAGING
Diameter 14 Lb. (6.3 kg) Coil
in. (mm) [ 56 Lb. (25.4 kg)
Master Sealed Pail ]
5/64 (2.0) ED030925
MECHANICAL PROPERTIES
- As Required per AWS A5.29-98 (Standard AWS Test Plate)
NOTE: Pipeliner elec-
trodes are manufactured
under lot control. A
Certificate of Test showing
actual deposit chemistry
and mechanical properties
per AWS A5.29 is avail-
able on request from the
factory for every lot of
electrode.
(Fax 216-383-8386).
(1)
The strength and elongation properties reported were obtained from a .505" tensile specimen artificially aged at 220°F
(104°C) for 48 hours, as permitted by AWS A5.29-98. A naturally aged tensile specimen may take months to achieve the
specified properties. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weld-
ment geometry, the metallurgical structure of the weld deposit and other factors.
(2)
Standard testing completed to AWS test plate specifications.
Figure 1 below shows results on a simulated pipe joint.
Charpy V-Notch
Yield Strength Tensile Strength
(1)
Elongation
(1)
ft•lbf (Joules)
(2)
Hardness
psi (MPa) psi (MPa) (%) @ -20°F (-29°C) @-40°F (-40°C) Rockwell B
Requirements 58,000 (400) 70,000 - 90,000 20 20 (27) Not . Not
AWS E71T8-K6 min. (483 - 620) min. min. Required . Required
Typical Results 63,000 79,000 30 173 - 251 147 . NA
(434) (545) (234 - 340) (199) ..
04020 60 80 100 120 140 160 180 200 220 240
0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
CVN (ft-lbs)
% of Total Samples
Figure 1 – CVN Distribution
E6010 Root Pass on Simulated Pipe Joint
@ -4˚F (-20˚C)
NR-207XP virtually eliminates CVN values below 42 ft•lbf (56 joules).
42ft•lbf (56joules)