Lincoln Electric 455 M Welder User Manual


 
A-1
INSTALLATION
POWER WAVE 455M (CE)
A-1
TECHNICAL SPECIFICATIONS - POWER WAVE 455M (CE) (K2202-2)
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSIONS
PROCESS CURRENT RANGE (DC) CURRENT
TEMPERATURE RANGES
INPUT AT RATED OUTPUT - THREE PHASE ONLY
INPUT
VOLTS
380V - 60HZ.
380V - 50HZ.
415V - 60HZ.
415V - 50HZ.
OPEN
CIRCUIT
VOLTAGE
75 VDC
INPUT
VOLTAGE /
FREQUENCY
380V HZ.
415V HZ.
HEIGHT
663 mm
(26.10 in)
WIDTH
505 mm
(19.86 in)
DEPTH
835 mm
(32.88 in)
WEIGHT
114 kg.
(250 lbs.)
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
40A
40A
TYPE 75°C
GROUND WIRE
IN CONDUIT
AWG[IEC] SIZES
(mm
2
)
10 (6)
10 (6)
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG[IEC] SIZES
(mm
2
)
8 (10)
8 (10)
INPUT AMPERE
RATING ON
NAMEPLATE
36A
33A
DUTY
CYCLE
100%
100%
MIG/MAG
FCAW
SMAW
GTAW
Pulse
50-570 Amps
40-570 Amps
30-570 Amps
15-500 Amps
5-750 Amps
PULSE
VOLTAGE
RANGE
5 - 55 VDC
AUXILIARY
POWER
40 VDC AT
10 AMPS
220 VAC AT
5 AMPS
PULSE AND
BACKGROUND
TIME RANGE
100 MICRO SEC. -
3.3 SEC.
CURRENT
RANGE
AMPS
5 - 570A
PULSE
FREQUENCY
0.15 - 1000 Hz
INPUT CURRENT
AMPS
36A
36A
33A
33A
INPUT CURRENT
AMPS
48A
48A
44A
44A
OUTPUT CONDITIONS
AMPS / VOLTS / DUTY CYCLE
400A@36V. 100%
400A@36V. 100%
400A@36V. 100%
400A@36V. 100%
OUTPUT CONDITIONS
AMPS / VOLTS / DUTY CYCLE
500A@40V. 60%
500A@40V. 60%
500A@40V. 60%
500A@40V. 60%
OPERATING TEMPERATURE RANGE
-20°C to 40°C
STORAGE TEMPERATURE RANGE
-40°C to 40°C