Lincoln Electric IM10044 Welder User Manual


 
VANTAGE® 575 CUMMINS
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS - VANTAGE® 575 CUMMINS (K2170-2)
Make/Model Description Speed (RPM) Displacement Starting Capacities
cu. in. (ltrs.) System
4 cylinder High Idle 1590 199(3.3)
12VDC Battery &
Fuel: 25 gal.
Cummins 48 HP (36kw) starter (94.6 L)
B3.3 1500 RPM Full Load 1500
Bore x Stroke inch (mm)
Oil: 2 gal. (7.5L)
Diesel Engine
Low Idle 1300
3.74 X 4.53
Radiator Coolant:
(95 x 115mm) 2.6gal. (9.8L)
INPUT - DIESEL ENGINE
RATED OUTPUT @ 104°F(40°C) - WELDER
Duty Cycle Welding Output Volts at Rated Amps
100% 450 Amps (DC multi-purpose) 38 Volts
60% 500 Amps (DC multi-purpose) 40 volts
PHYSICAL DIMENSIONS
Height
(2)
Width Depth Weight
42.0 in 32.7 in. 63.1 in. 1625 lbs.
(1066.8 mm) (830.1mm) (1603mm) (737kg)
(Approx)
1. Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2. Top of Enclosure, add 7.0” (177.8mm) for exhaust pipe.
OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR
Welding Range
30 - 575 Amps CC/CV
20 - 250 Amps TIG
Open Circuit Voltage
60 Max OCV @ 1590 RPM
Auxiliary Power
(1)
(50 Hz)
Outlets x Phase Voltage Power Amps
1 x 3ph 415 Volts 20 Kva 32 Amps
2 x 1ph 240 Volts 7.2 Kva 15 Amps