Lincoln Electric IM640-A Welding System User Manual


 
B-5
OPERATION
B-5
ENGINE OPERATION
Do not adjust the high idle engine speed (rpm) above
the factory setting specification as this will overspeed
the air compressor and void it’s warranty.
------------------------------------------------------------------------
STARTING INSTRUCTIONS
Be sure all Pre-Operation Maintenance has been per-
formed. (See INSTALLATION section of this manual).
Set the air compressor “ON/OFF” switch in the “OFF”
position. To start the engine, place ignition toggle
switch in the “ON” position. Engage the starter button.
When the engine starts running, observe the engine oil
pressure. If no pressure shows within 30 seconds,
stop the engine and consult the engine operating man-
ual. To stop the engine, place the ignition toggle switch
in the “OFF” position.
When an engine is started for the first time, some of
the oil will be needed to fill the passages of the lubri-
cating system. Therefore, on initial starting, run the
engine for about five minutes and then stop the engine
and recheck the oil. If the level is down, fill to the full
mark again. The engine controls were properly set at
the factory and should require no adjusting when
received.
For added safety always operate the welder with the
doors closed. Further, leaving the doors open changes
the designed air flow and may cause engine, genera-
tor or compressor overheating.
COLD WEATHER STARTING
Never use any other starting aids, such as ether,
when using the Thermostart system.
------------------------------------------------------------------------
When overnight temperatures are between 10°F (-
12°C) and freezing, use the standard “Thermostart”
starting system installed on all engines. Follow the
instructions on the start panel nameplate and in the
engine manual shipped with the welder. With fully
charged batteries and the proper weight oil, the
“Thermostart” system operates satisfactorily even
down to about 0°F (-18°C).
AIR COMPRESSOR (SAE400 WELDN AIR only)
Cylinder head stud torque must be checked after initial
8 to 10 hours of operation. See compressor operator’s
manual for details. Compressor mounting bolts should
be checked for tightness after initial 8 to 10 hours of
operation.
TYPICAL FUEL CONSUMPTION
The typical fuel consumption of the SAE400 and
SAE400 WELD’N AIR for various operating scenarios
is shown below:
Low Idle - No Load .35 gal./ hr.
1100 RPM (1.32 L./hr.)
High Idle - No Load .75 gal./hr.
1800 RPM (2.84 L./hr.)
Welding Load 1.92 gal./hr.
400 Amps, 40 Volts (7.27 L./hr.)
Auxiliary Power .96 gal./hr.
3000VA (3.63 L./hr.)
Air Compressor 1.04 gal./hr.
(SAE400 WELD’N AIR Only) (3.94 L./hr.)
400 Amps, 40 Volts Load 2.22 gal./hr.
with Air Compressor “ON” (8.40 L./hr.)
(SAE400 WELD’N AIR Only)
Auxiliary Power 1.20 gal./hr.
3000 VA with (4.54 L./hr.)
Air Compressor “ON”
(SAE400 WELD’N AIR Only)
SAE400 & SAE400 WELDN AIR
WARNING