Lincoln Electric IM959 Welder User Manual


 
E-2
TROUBLESHOOTING
E-2
COOL ARC® 35
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E43 alarm after initial installation of
power source and cooler, or when
attaching a water cooled torch.
1. Torch water hoses need to be
primed.
2. There is a blockage in the path of
the coolant.
1. After turning the system ON,
press the COOL ARC® 35 push
button to begin priming procedure.
2. Verify that the coolant path is
clear – that there are no twists,
kinks, or pinch-points in the
coolant hoses.