Lincoln Electric IM959 Welder User Manual


 
K2630-1 COOL ARC® 35
350VDC (From V310-T AC/DC & V311-T AC/DC)
0.35 Amps
50 psi (345 kPa) (3.5 bar)Max.
1.2 gal/min. (4.6 liter/min) Max.
53-57 psi (365-393 kPa)
.45-.60 gal/min. (1.7-2.3 liter/min)
1.3 gal. ( 5 liters)
For Use Above Freezing: Clean tap, distilled or de-ionized water.
For Use Below Freezing:
50% water and 50% pure ethylene glycol (reagent
or industrial grade) mixture.
DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak stoppers.
These coolants will damage the pump and block the small internal passageways of
the heat exchanger, affecting cooling performance. To acquire the proper coolant
contact a local welding distributor.
DO NOT USE: Pre-packaged welding industry coolants. These coolants may contain
oil-based substances, which attack the plastic components of the cooler. Once added
to the cooler, these substances are impossible to purge from the water lines and heat
exchanger.
29.8 lbs. (13.5 kg)
42.0 lbs. (19.0 kg)
24.5 in. (622 mm)
11.0 in. (280 mm)
10.0 in. (256 mm)
A-1
INSTALLATION
COOL ARC® 35
A-1
Product No. / Model
Input
Current Draw
Maximum Operating Pressure and Flow Rate
(Open Flow, Without Welding Torch Restriction)
Typical Operating Pressure and Flow Rate
(With Welding Torch Restriction)
Reservoir Size
Recommended Coolant
Shipping
Weight
Reservoir
Full (Water)
L
W
Dimensions
H
TECHNICAL SPECIFICATIONS – COOL ARC
®
35
Temperature Conversion
Chart
Celcius ºC*
20
30
40
50
60
70
80
90
Fahrenheit ºF
68
86
104
122
140
158
176
194