Miller Electric 333 Welder User Manual


 
OM-223 194 Page 10
3-4. Installing Gas Supply
Ref. ST-148 265-B / Ref. ST-149 827-B / Ref. ST-158 697-A
2
CO
2
Gas
1
Argon Gas
OR
3
Chain gas cylinder to running gear,
wall, or other stationary support so
cylinder cannot fall and break off
valve.
1 Regulator/Flow Gauge
Install so face is vertical.
2 Gas Hose Connection
3 Flow Adjust
Typical flow rate is 0.9 liters per
minute. Check wire manufactur-
er’s recommended flow rate. This
flow gauge can be adjusted be-
tween 2.36 and 11.8 liters per min-
ute.
3-5. Installing Wire Spool and Adjusting Hub Tension
Nov. 16, 2005
When a slight force is needed to turn spool, tension is set.
Tools Needed: