Miller Electric 394F Welder User Manual


 
OM-222 394 Page 28
8-2. Diagnostics (Continued)
WELD WAIT
The weld wait error indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
MOTR COM
The motor communication error indi-
cates motor board lost data communica-
tions. Press Jog/Purge button to clear error.
PLS WAIT
The uim communication error indicates
user interface board lost data
communications. Press Jog/Purge button
to clear error.
OVER CRNT
The over current error indicates welding
power source primary current is too high.
Check and correct input power. Press Jog/
Purge button to clear error.
LOW WFS
The low wire feed speed error indicates
actual wire feed speed is lower than wire
feed speed command. Check for
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
E STOP
The emergency stop error occurs if the
user presses an emergency stop button.
Reset the emergency stop button and press
Jog/Purge button to clear error.
RMD DONE
The RMD done error indicates the RMD
demo is completed. Press Jog/Purge button
to clear error.
OVER AVER
The over average error indicates that cur-
rent is outside the average range for the set
program parameters. Check and correct
program parameters. Press Jog/Purge but-
ton to clear error.
REL TRIG
The release trigger error indicates the
user held the trigger when starting a weld
program Press Jog/Purge button to clear
error.
ERR UNKN
The unknown error indicates a malfunc-
tion in the system somewhere. Press Jog/
Purge button to clear error.
WELD MOTR
COM
PLS
WAIT
Indicates a weld
cycle wait error.
Indicates a motor
communication error.
Indicates a UIM
communication error.
OVER
CRNT
LOW
WFS
Indicates an
overcurrent error.
Indicates a low WFS
command error.
E
STOP
Indicates an
emergency stop error.
RMD
DONE
OVER
AVER
Indicates an arc
error.
Indicates an over
average current error.
REL
TRIG
ERR
UNKN
Indicates a trigger
closed error.
Indicates an
unknown error.