Miller Electric 4500 Series Welder User Manual


 
OM-221 677 Page 13
SECTION 6 MAINTENANCE AND TROUBLESHOOTING
6-1. Routine Maintenance
Y Disconnect power before maintaining.
. Maintain more often during severe conditions.
3 Months
Replace unreadable labels. Clean and tighten weld terminals.
Repair or replace cracked weld
cable.
Repair or replace cracked gas
hose.
Replace o-ring in Electrode/Gas
Output receptacle if cracked.
6 Months
Blow out or vacuum inside.
OR
6-2. Troubleshooting
Trouble Remedy
No weld output; fan does not run.
Place line disconnect switch in On position (see Section 4-4).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-4).
Check for proper input power connections (see Section 4-4).
No weld output; fan on.
Check and replace if necessary.
Tighten wire feeder connection to Remote 14 receptacle.
Unit overheated. Allow unit to cool (see Section 3-3).
Fan not operating; weld output
available
Check for and remove anything blocking fan movement.
ava
il
a
bl
e.
Have Factory Authorized Service Agent check fan motor.