Miller Electric and DS-75D16 Welder User Manual


 
OM-230 300 Page 17
4-14. Installing Non-PD (Old Style) Wire Guides
Ref. 804 732-A
Installing wire guides with non- PD (old-
style) drive rolls
. Non-PD (old-style) wire guides and
drive rolls should be used with 5/64 in
(2.0 mm) and larger diameter wire.
1 PD Inlet Guide
2 Intermediate Guide
3 Guide Holder
4 Exit Guide
5 Set Screw
6 Pressure Door Assembly
Open pressure door assembly.
Lift up drive roll swing arms.
Install PD inlet guide.
. Do not tighten set screw to secure inlet
guide.
. Set screw may be used to secure PD
inlet guide replacements such as wire
straighteners or conduit adapters.
Remove screw securing intermediate guide
holder. (Guide holder is located between
the lower front and rear drive roll carriers.)
Rotate guide holder 180 degrees and rein-
stall.
Install intermediate guide into guide holder
and tighten set screw.
Loosen set screw, insert exit guide into
block near brass power pin gun connection
and secure with set screw.
. When using smaller diameter inlet
guide (219108) with non-PD (old style)
drive rolls, a 1/4 in (6 mm) gap will be
present between the guide and drive
roll.
Tools Needed:
1/16, 1/8, 5/32 in
2
1
3
4
5
6