Miller Electric 75 Welder User Manual


 
OM-228 956 Page 30
7-2. Diagnostics (Continued)
ERR TEMP
The temperature error indicates welding
power source has overheated and
shutdown. The error may be cleared by
allowing unit to cool down, and pressing the
Jog/Purge button.
ERR LINE
The line error indicates input power is
outside of unit operating range. Check and
correct input power. Press Jog/Purge
button to clear error.
ERR ARC
The arc error indicates an arc outage
occurred possibly from a wire feeder error
or power source error. Check wire feeder
and power source. Press Jog/Purge button
to clear error.
ERR POL
The polarity error indicates the polarity is
different than the selected polarity. Check
and correct weld cable connections. Press
Jog/Purge button to clear error.
UNIT MEM
The unit memory error indicates the PCM
board lost memory data. Press Jog/Purge
button to clear error.
UIM MEM
The uim memory error indicates user
interface board lost memory data. Press
Jog/Purge button to clear error.
MOTR MEM
The motor memory error indicates motor
board lost memory data. Press Jog/Purge
button to clear error.
WELD WAIT
The weld wait error indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
MOTR COM
The motor communication error indi-
cates motor board lost data communica-
tions. Press Jog/Purge button to clear error.
PLS WAIT
The uim communication error indicates
user interface board lost data
communications. Press Jog/Purge button
to clear error.
OVER CRNT
The over current error indicates welding
power source primary current is too high.
Check and correct input power. Press Jog/
Purge button to clear error.
LOW WFS
The low wire feed speed error indicates
actual wire feed speed is lower than wire
feed speed command. Check for
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
UNIT
MEM
UIM
MEM
MOTR
MEM
WELD
WAIT
MOTR
COM
PLS
WAIT
Indicates a memory
CRC PCM error.
Indicates a memory
CRC UIM error.
Indicates a memory
CRC motor error.
Indicates a weld
cycle wait error.
Indicates a motor
communication error.
Indicates a UIM
communication error.
OVER
CRNT
LOW
WFS
Indicates an
overcurrent error.
Indicates a low WFS
command error.
ERR
TEMP
ERR
LINE
ERR
ARC
ERR
POL
Indicates a
temperature error.
Indicates a line
error.
Indicates an arc
error.
Indicates a polarity
error.