Miller Electric Big Blue 400 KX Welding System User Manual


 
OM-4423 Page 15
4-6. AC Generator Power Curve
220 346B
The ac power curve shows the gen-
erator power in amperes.
AC AMPERES IN 110V MODE
AC AMPERES IN 220V MODE
AC VOLTS
0 20 40 60 80 100 120 140
0 10203040506070
0
20
40
60
80
100
120
0
40
80
120
160
200
240
Notes
16 Gauge (.063 in)
22 Gauge (.031 in)
24 Gauge (.025 in)
20 Gauge (.037 in)
18 Gauge (.050 in)
14 Gauge (.078 in)
1/8 in (.125 in)
3/16 in (.188 in)
1/4 in (.25 in)
5/16 in (.313 in)
3/8 in (.375 in)
1/2 in (.5 in)
MATERIAL THICKNESS REFERENCE CHART