SECTION 7 OPERATING AUXILIARY EQUIPMENT
7-1. 110 Volt Receptacles
Ref. 217 358-B
1 110/55V 32 A AC Receptalce RC11
2 110/55V 16A AC Receptacle RC12
Receptacles RC11 and RC12 supply 60 Hz
single-phase power at weld/power speed.
Maximum output from RC11 is 3.5 kVA/kW.
Maximum output from RC12 is 1.8 kVa/kW.
Maximum combined output of RC11 and
RC 12 is 4.4 kVa/kW.
3 Circuit Breaker CB6
4 Circuit Breaker CB5
CB6 protects RC12 from overload. If a cir-
cuit breaker opens, the receptacle does not
work. Press button to reset breaker.
Circuit breaker CB5 protects receptacle
RC11 and the generator winding from over-
load. If CB5 opens, the receptacles do not
work. Place CB5 switch in On position to
reset circuit breaker.
. If a circuit breaker continues to open,
contact Factory Authorized Service
Agent.
. Generator power decreases as weld
output increases.