. A complete Parts List is available at www.MillerWelds.com
OM-222 Page 17
4-11. Remote 14 Receptacle Information
Socket Information
24 VOLTS AC
A 24 volts ac. Protected by supplementary protector CB2.
24 VOLTS AC
B Contact closure to A completes 24 volts ac contactor control circuit.
C Command reference; 0 to +10 volts dc.
REMOTE OUTPUT CONTROL
D Remote control circuit common.
E 0 to +10 volts dc input command signal from remote control.
F Current feedback; 1 volt per 100 amperes.
H Voltage feedback; 1 volt per 10 arc volts.
115 VOLTS AC
I 115 volts, 15 amperes, 60 Hz ac. Protected by supplementary protector CB1.
115 VOLTS AC
J Contact closure to I completes 115 volts ac contactor control circuit.
GND
K
G
Chassis common.
Circuit common for 24 and 115 volts ac circuits.
REMOTE POWER ON/OFF
*
To remote On/Off switch
REMOTE POWER ON/OFF
*
T
o
remote
O
n
/Off
sw
i
tc
h
.
REMOTE VOLTAGE SENSING
* Voltage sensing signal from Negative (-) weld output terminal.
REMOTE VOLTAGE SENSING
* Voltage sensing signal from Positive (+) weld output terminal.
* Not Used
4-12. Connecting Remote Control
Ref. ST-800 101-D / ST-141 127-D
1 Remote 14 Receptacle RC8
Connect remote control to RC8.
OR
OR
AJ
B
K
I
C
L
NH
D
M
G
E
F
1