Miller Electric 456P Welding System User Manual


 
OM-185 648 Page 12
SECTION 3 INSTALLATION
3-1. Specifications
Input
Power
Rated Welding
Output
Voltage
Range
Maximum
Open-
Circuit
Amperes Input
At Rated Load
Output 60 Hz,
Three-Phase
Voltage DC
400 V KVA KW
Three Phase
450 A @ 38 Volts DC,
100% Duty Cycle;
565 A @ 38 Volts DC,
60% Duty Cycle
10 38 95 31 21.6 19.4
3-2. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
Y Exceeding duty cycle can
damage unit and void war-
ranty.
Overheating
0
15
A/V
OR
Reduce Duty Cycle
Minutes
duty1 4/95 SA-181 560
Continuous Welding
100% Duty Cycle At 450 Amperes 60% Duty Cycle At 565 Amperes
6 Minutes Welding 4 Minutes Resting