. A complete Parts List is available at www.MillerWelds.com
OM-1327 Page 16
3-9. Connecting XR Edge, XR-A Gun, XR-A Python, Or XR - Aluma-Pro
803 569-A / Ref. 803 570 -A / Ref. 803 463
. XR Edge guns prior to serial no.
LE079101 require an adapter
cord (part no. 195 498).
1 Gun End
2 Gun Liner
3 Wire Outlet Guide
Trim excess liner from end of gun
so no more than 3/32 in (2.4 mm) of
liner extends past wire outlet guide.
4 Gun Securing Knob
Loosen securing knob. Insert gun
end through opening until it bottoms
against drive assembly (make sure
gun end does not touch drive rolls).
Tighten knob.
Be sure to change drive rolls to the
proper size and type.
5 Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
4
32
3/32 in
(2.4 mm)
. Be sure to trim liner to proper extension.
1
5