OM-1500-9 Page 17
SECTION 6 − OPERATION
6-1. Operational Terms
The following is a list of terms and their definitions as they apply to this wire feeder:
General Terms:
Cold Wire Jog Feeding wire without contactor or gas valve being energized.
Sequence A portion of the weld program, such as preflow, run-in, start, weld, crater, burnback, and postflow.
Weld Program A group of sequences that make up a weld cycle.
6-2. Power Switch
1 Power Switch
1
802 809-A
6-3. Program Push Button
1
3
Program
2
1 Program Display
The number of the active program
is displayed.
2 Program Push Button
Press button to activate program
select feature. To change the pro-
gram number, press the Program
push button and rotate the Adjust
control.
3 Program Push Button LED
The LED lights to indicate the Pro-
gram push button is active.
1
2
3
Non-CE Models
CE Models