Miller Electric S-75S Welder User Manual


 
OM-223 605 Page 12
5-2. Rear Panel Connections And Rotating Drive Assembly
Ref. 804 183-A / 804 184-A
2
4
1 14-Pin Control Cable - 10 ft
(3.0 m)
2 Shielding Gas Valve Fitting
Connect customer-supplied gas
hose with 5/8-18 right-hand
threads.
. Shielding gas pressure not to
exceed 90 PSI (620 kPa).
3 Weld Cable
4 Weld Cable Screw - Screw
Size (.375 16 X 1.50)
. Note two weld cable connec-
tions: 0 to 350 Amps, and 350
Amps and above.
5 Drive Assembly
6 Drive Assembly Rotation
Knob
To rotate the drive assembly, loos-
en drive assembly rotation knob,
rotate drive assembly, and tighten
knob.
7 Rating Label Location
9/16 in
Tools Needed:
5
6
1
7
0 to 350 Amps
weld connection
350 Amps and above
weld connection
3